Test suite results for test file ../packages/fcl-process/tests/testprocess.pp

Test run data :

Run ID:
Operating system: solaris
Processor: sparc
Version: 3.3.1
Fails/OK/Total: 48/9112/9160
Version: 3.3.1
Full version: 3.3.1-15677-g5e00358f13
Comment: -O2 -Xn -Cg -Fd
Machine: s11-sparc
Category: 1
SVN revisions: 5e00358f13:d6cf3c98d0:e657d6a07d:485b31de21
Submitter: pierre
Date: 2024/05/08 23:46:00
Previous run: 947658
Next run: 948938

Hide skipped tests

Hide successful tests

Test file "../packages/fcl-process/tests/testprocess.pp" information:

t_id 6948
t_adddate 2024/02/15 15:41:42
t_result 0
t_knownrunerror 0

Detailed test run results:

tr_idruntr_oktr_skiptr_result
526006145948284FalseFalseFailed to run

Record count: 1

Log of 948284:

 Time:04.233 N:23 E:3 F:1 I:0
  TTestProcess Time:04.233 N:23 E:3 F:1 I:0
    00.000  TestHookUp
    00.041  TestSimple
    00.042  TestSimpleParam
    00.004  TestExitStatus
    01.003  TestWaitFor
    01.003  TestOptionWaitOnExit
    00.522  TestTerminate
    00.202  TestPipes
    00.103  TestWritePipes
    00.202  TestStdErr
    00.202  TestStdErrToOutput
    00.101  TestInputFile  Failed: Read input
      Exception:   Read input
      at   $001BA208
    00.101  TestOutputFile
    00.101  TestStdErrFile
    00.101  TestStdErrToStdOut
    00.101  TestInputNull
    00.101  TestOutputFileExistingAppend
    00.201  TestOutputFileExistingTruncate
    00.101  TestOutputFileExistingAtStart
    00.000  TestPipeOut  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $002AF70C
    00.000  TestPipeOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $002AF70C
    00.000  TestPipeInOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $002AF70C
    00.000  TestPipeRestart

Number of run tests: 23
Number of errors:    3
Number of failures:  1

List of errors:
  Error: 
    Message:           TTestProcess.TestPipeOut: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $002AF70C

  Error: 
    Message:           TTestProcess.TestPipeOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $002AF70C

  Error: 
    Message:           TTestProcess.TestPipeInOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $002AF70C


List of failures:
  Failure: 
    Message:           TTestProcess.TestInputFile: Read input
    Exception class:   EAssertionFailedError
    Exception message: Read input
        at   $001BA208




No Source in TestSuite DataBase.