Test suite results for test file ../packages/fcl-process/tests/testprocess.pp

Test run data :

Run ID:
Operating system: solaris
Processor: sparc
Version: 3.3.1
Fails/OK/Total: 57/9104/9161
Version: 3.3.1
Full version: 3.3.1-15627-g64f2e4b-unpushed
Comment: -Agas -Cg -Fd
Machine: unstable10s
Category: 1
SVN revisions: e601156:d3fd0b8:64f2e4b:6a10963
Submitter: pierre
Date: 2024/04/28 12:53:00
Previous run: 940458
Next run: 941965

Hide skipped tests

Hide successful tests

Test file "../packages/fcl-process/tests/testprocess.pp" information:

t_id 6948
t_adddate 2024/02/15 15:41:42
t_result 0
t_knownrunerror 0

Detailed test run results:

tr_idruntr_oktr_skiptr_result
482398449941218FalseFalseFailed to run

Record count: 1

Log of 941218:

 Time:04.304 N:23 E:3 F:1 I:0
  TTestProcess Time:04.304 N:23 E:3 F:1 I:0
    00.001  TestHookUp
    00.042  TestSimple
    00.042  TestSimpleParam
    00.020  TestExitStatus
    01.016  TestWaitFor
    01.015  TestOptionWaitOnExit
    00.521  TestTerminate
    00.205  TestPipes
    00.104  TestWritePipes
    00.204  TestStdErr
    00.204  TestStdErrToOutput
    00.102  TestInputFile  Failed: Read input
      Exception:   Read input
      at   $000A1E7C
    00.103  TestOutputFile
    00.102  TestStdErrFile
    00.102  TestStdErrToStdOut
    00.103  TestInputNull
    00.102  TestOutputFileExistingAppend
    00.204  TestOutputFileExistingTruncate
    00.103  TestOutputFileExistingAtStart
    00.002  TestPipeOut  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.001  TestPipeOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.002  TestPipeInOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.001  TestPipeRestart

Number of run tests: 23
Number of errors:    3
Number of failures:  1

List of errors:
  Error: 
    Message:           TTestProcess.TestPipeOut: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570

  Error: 
    Message:           TTestProcess.TestPipeOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570

  Error: 
    Message:           TTestProcess.TestPipeInOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570


List of failures:
  Failure: 
    Message:           TTestProcess.TestInputFile: Read input
    Exception class:   EAssertionFailedError
    Exception message: Read input
        at   $000A1E7C




No Source in TestSuite DataBase.

Link to SVN view of ../packages/fcl-process/tests/testprocess.pp source.