Test suite results for test file ../packages/fcl-process/tests/testprocess.pp

Test run data :

Run ID:
Operating system: solaris
Processor: sparc
Version: 3.3.1
Fails/OK/Total: 57/9104/9161
Version: 3.3.1
Full version: 3.3.1-15620-gb18c93d-unpushed
Comment: -Cg -Fd
Machine: unstable10s
Category: 1
SVN revisions: 1de3aba:0481a46:b18c93d:61397d4
Submitter: pierre
Date: 2024/04/27 13:52:00
Previous run: 928787
Next run: 941232

Hide skipped tests

Hide successful tests

Test file "../packages/fcl-process/tests/testprocess.pp" information:

t_id 6948
t_adddate 2024/02/15 15:41:42
t_result 0
t_knownrunerror 0

Detailed test run results:

tr_idruntr_oktr_skiptr_result
477744736940467FalseFalseFailed to run

Record count: 1

Log of 940467:

 Time:04.306 N:23 E:3 F:1 I:0
  TTestProcess Time:04.306 N:23 E:3 F:1 I:0
    00.001  TestHookUp
    00.043  TestSimple
    00.042  TestSimpleParam
    00.020  TestExitStatus
    01.016  TestWaitFor
    01.016  TestOptionWaitOnExit
    00.522  TestTerminate
    00.205  TestPipes
    00.104  TestWritePipes
    00.205  TestStdErr
    00.204  TestStdErrToOutput
    00.102  TestInputFile  Failed: Read input
      Exception:   Read input
      at   $000A1E7C
    00.103  TestOutputFile
    00.102  TestStdErrFile
    00.102  TestStdErrToStdOut
    00.103  TestInputNull
    00.102  TestOutputFileExistingAppend
    00.203  TestOutputFileExistingTruncate
    00.103  TestOutputFileExistingAtStart
    00.002  TestPipeOut  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.002  TestPipeOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.002  TestPipeInOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $00197570
    00.001  TestPipeRestart

Number of run tests: 23
Number of errors:    3
Number of failures:  1

List of errors:
  Error: 
    Message:           TTestProcess.TestPipeOut: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570

  Error: 
    Message:           TTestProcess.TestPipeOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570

  Error: 
    Message:           TTestProcess.TestPipeInOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $00197570


List of failures:
  Failure: 
    Message:           TTestProcess.TestInputFile: Read input
    Exception class:   EAssertionFailedError
    Exception message: Read input
        at   $000A1E7C




No Source in TestSuite DataBase.

Link to SVN view of ../packages/fcl-process/tests/testprocess.pp source.