Test suite results for test file ../packages/fcl-process/tests/testprocess.pp

Test run data :

Run ID:
Operating system: solaris
Processor: x86_64
Version: 3.3.1
Fails/OK/Total: 33/9383/9416
Version: 3.3.1
Full version: 3.3.1-15669-g5333e6b-unpushed
Comment: -O2 -Xn -Fd
Machine: unstable10x
Category: 1
SVN revisions: e60a7d0:5333e6b:e657d6a:6a10963
Submitter: pierre
Date: 2024/05/06 03:29:00
Previous run: 945900
Next run: 955520

Hide skipped tests

Hide successful tests

Test file "../packages/fcl-process/tests/testprocess.pp" information:

t_id 6948
t_adddate 2024/02/15 15:41:42
t_result 0
t_knownrunerror 0

Detailed test run results:

tr_idruntr_oktr_skiptr_result
514593600946432FalseFalseFailed to run

Record count: 1

Log of 946432:

 Time:04.343 N:23 E:3 F:1 I:0
  TTestProcess Time:04.343 N:23 E:3 F:1 I:0
    00.004  TestHookUp
    00.050  TestSimple
    00.044  TestSimpleParam
    00.009  TestExitStatus
    01.005  TestWaitFor
    01.008  TestOptionWaitOnExit
    00.524  TestTerminate
    00.226  TestPipes
    00.150  TestWritePipes
    00.211  TestStdErr
    00.201  TestStdErrToOutput
    00.101  TestInputFile  Failed: Read input
      Exception:   Read input
      at   $000000000058CB9A
    00.101  TestOutputFile
    00.101  TestStdErrFile
    00.101  TestStdErrToStdOut
    00.102  TestInputNull
    00.101  TestOutputFileExistingAppend
    00.201  TestOutputFileExistingTruncate
    00.101  TestOutputFileExistingAtStart
    00.001  TestPipeOut  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $0000000000646115
    00.000  TestPipeOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $0000000000646115
    00.001  TestPipeInOutToFile  Error: EProcess
      Exception:   Cannot get handle. Process not active
      at   $0000000000646115
    00.000  TestPipeRestart

Number of run tests: 23
Number of errors:    3
Number of failures:  1

List of errors:
  Error: 
    Message:           TTestProcess.TestPipeOut: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $0000000000646115

  Error: 
    Message:           TTestProcess.TestPipeOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $0000000000646115

  Error: 
    Message:           TTestProcess.TestPipeInOutToFile: Cannot get handle. Process not active
    Exception class:   EProcess
    Exception message: Cannot get handle. Process not active
        at   $0000000000646115


List of failures:
  Failure: 
    Message:           TTestProcess.TestInputFile: Read input
    Exception class:   EAssertionFailedError
    Exception message: Read input
        at   $000000000058CB9A




No Source in TestSuite DataBase.

Link to SVN view of ../packages/fcl-process/tests/testprocess.pp source.